"Failed to receive ICAP header" Error appears while connecting from storage filer

book

Article ID: 227845

calendar_today

Updated On:

Products

Protection Engine for NAS

Issue/Introduction

"Failed to receive ICAP header" Error appears while connecting from storage filer, in this case Citrix application delivery controller (ADC)

Note: ICAP Configuration in SPE should be correct and should be able to ping the filer and telnet the configured port.

Cause

ICAP RESPMOD URL : ICAP://<SPE Server IP>/RESPMOD

 

Environment

Release : 8.2

Component : NA

Resolution

Replace ICAP RESPMOD URL with : ICAP://<SPE Server IP>/SYMCScanRespEx-AV

For more details, Refer : SPE_NAS_SDK_Guide.pdf at Related Documents