ALERT: Some images may not load properly within the Knowledge Base Article. If you see a broken image, please right-click and select 'Open image in a new tab'. We apologize for this inconvenience.

Receiving CC12 when generating an Endevor Processor

book

Article ID: 226865

calendar_today

Updated On:

Products

Endevor Software Change Manager (SCM)

Issue/Introduction

Trying to generate a processor and receiving a CC12 in the TRANSLAT step, however, can't find what the error is.

       C1X0010I  STEP TRANSLAT PROGRAM C1GJTRNS COMPLETED, RC=0012 
C1G0129E  STEP TRANSLAT RC (0012) EXCEEDS THE MAX RC (0004)

 

Where to look for what the error is? 

Environment

Release :  18.0 18.1

Component : CA Endevor Software Change Manager

Resolution

Return to the top of the output and do a Find for an E followed by a blank starting in col 29 -   

                           F 'e '  29

 

This will find the E level errors in the processors like -

                C1X0244E  DUPLICATE KEYWORD FOUND - MACLIB1