Trying to run canned CULPRIT reports (e.g. PMARPT01) results in this abend:
21.29.27 JOB06188 +IDMS RUN-UNIT CANCELLED DUE TO PROGRAM REQUEST
21.29.27 JOB06188 IEA995I SYMPTOM DUMP OUTPUT 685
685 USER COMPLETION CODE=4039 REASON CODE=00000000
685 TIME=21.29.27 SEQ=65357 CPU=0000 ASID=007A
685 PSW AT TIME OF ERROR 078D1000 8C17F5B2 ILC 2 INTC 0D
685 NO ACTIVE MODULE FOUND
685 NAME=UNKNOWN
685 DATA AT PSW 0C17F5AC - 00181610 0A0D58D0 D00498EC
and also this LE runtime error is seen:
CEE3250C The system or user abend U2222 R=NULL was issued.
From compile unit CULPDRES at entry point CULPDRS2 at compile unit offset +0002C2C4 at entry offset +000290A4
at address 000416AC.
Release : All supported releases.
Component : Culprit
These errors are normally an indication that CULPRIT is having trouble loading the culprit source module(s) from the dictionary.
Make sure that the DICTNAME= specification in the CULPRIT SYSIN is correct and the dictionary is properly specified from a JCL and DMCL perspective, and is available.