PanExec PANEIPL getting a S122 abend in PEIPL53
search cancel

PanExec PANEIPL getting a S122 abend in PEIPL53

book

Article ID: 226292

calendar_today

Updated On:

Products

Panvalet

Issue/Introduction

 Planning to upgrade z/OS and testing on a test LPAR.  When starting  PanExec  PANEIPL, getting the following error:

 PL090 PANEXEC 5.3C 0609 SYSTEM PROCESSING START                        
 IEA995I SYMPTOM DUMP OUTPUT  063                                       
 SYSTEM COMPLETION CODE=122  REASON CODE=00000000                       
  TIME=14.15.57  SEQ=00117  CPU=0000  ASID=0025                         
  PSW AT TIME OF ERROR  078D2000   8001E8A6  ILC 4  INTC 0D             
    ACTIVE MODULE           ADDRESS=00000000_0001E370  OFFSET=00000536  
    NAME=PEIPL53                                                        
    DATA AT PSW  0001E8A0 - 181044E0  C4BA47F0  C4C20A0D                
    GR 0: 84122000   1: 84122000                                        
       2: 00006FE6   3: 0001A1DB                                        
       4: 0001A1DA   5: 0001A1DE                                        
       6: 8001D030   7: 00FC9580                                        
       8: 009FC7D8   9: 009FE8E0                                        
       A: 01D9A900   B: 0001E3F0                                        
       C: 0001E3F0   D: 0001A378                                        
       E: 0000000D   F: 00000000                                        
  END OF SYMPTOM DUMP                                                   
 IEF450I PANEIPLX PANEIPLX - ABEND=S122 U0000 REASON=00000000           
 IEF404I PANEIPLX - ENDED                                               
 $HASP395 PANEIPLX ENDED - ABEND=S122                                   

Environment

Release : 5.3

Component : Panexec (program management)

Resolution

PanExec is dependent on CAS9.   When CAIRIM(CAS9INIT) is not initialized, PANEIPL ABENDs with a S122.           

Verify that CAS9 has been started before starting PANEIPL.