UIM - Snmpcollector time over threshold alarms not working
search cancel

UIM - Snmpcollector time over threshold alarms not working

book

Article ID: 225908

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM) CA Unified Infrastructure Management SaaS (Nimsoft / UIM) CA Unified Infrastructure Management On-Premise (Nimsoft / UIM)

Issue/Introduction

Time over Threshold configured via the snmpcollector probe on the snmpcollector server hub via the probe's GUI is not working.

(1) Requirement: Restrict alarming for this CPUUtilizationLastMin metric but snmpcollector is not honoring the setting.

Time over threshold is set to 10 min and the sliding time window is at 15 min, polling interval is 5 min. 

Despite that getting alarms every time CPUUtilizationLastMin exceeds the threshold.

Following configuration guide was followed:

The Time Over Threshold Event Rule

(2) Despite the TOT configuration, alarms from this server continuously appear on the Operator Console Server.

 

Environment

Any UIM and snmpcollector version

Resolution

In this use case the alarm queues on snmpcollector hub were configured to send alarms upstream as well as nas replication was configured .

Because of TOT configured, the alarm queues from the snmpcollector hub to the primary hub should be removed 

Only NAS forwarding should happen via nas replication 

 

 

Additional Information

Install snmpcollector