An issue was found where a task in a JSCH got triggered twice because the period turnaround for that JSCH was performed twice within a minute.
Release : 12.3, 21.0
Component : AUTOMATION ENGINE
Software Bug
The issue has been confirmed to be a bug and has been fixed with:
Automation Engine 12.3.7+HF1 - available
Automation Engine 12.3.8 - available
Automation Engine 21.0.2 - available
Workaround:
Synchronize the time on all Servers!
The issue is more likely to occur when there is a time difference between WPs and PWP
U00003491 There is a time difference of '0/00:00:18' or '18' seconds to the Primary Server.
U00003491 There is a time difference of '0/00:00:19' or '19' seconds to the Primary Server.
U00003491 There is a time difference of '0/00:00:-22' or '-22' seconds to the Primary Server.