Getting a C1A0010E RC=0384-0003 error doing a Move of an Endevor processor
search cancel

Getting a C1A0010E RC=0384-0003 error doing a Move of an Endevor processor

book

Article ID: 225783

calendar_today

Updated On:

Products

Endevor

Issue/Introduction

When doing a Move of a Processor to Stage 2, getting the following allocation error:

                
13:29:16  C1A0010E  ALLOCATION ERROR RC=0384-0003, DDNAME=SYSLMOD                                             
13:29:16  C1A0011E  IKJ56877I FILE SYSLMOD NOT ALLOCATED, MUTUALLY INCLUSIVE PARAMETER MISSING                
                                                 

 

Environment

Release : 18.0 18.1

Component : Endevor Software Change Manager

Resolution

Verify that a Processor Load library is defined at Stage 2 in the System for the Processors- 

PROCESSOR TRANSLATION OUTPUT LIBRARIES:                 
STAGE 1 LOAD LIBRARY:     NDV.ADMIN.LOADLIB1
STAGE 1 LIST LIBRARY:     NDV.ADMIN.LISTLIB1  
STAGE 2 LOAD LIBRARY:    
STAGE 2 LIST LIBRARY: