GEN0915 HEALTH CHECKER FAILED within Database Management for Db2 Xmanager
search cancel

GEN0915 HEALTH CHECKER FAILED within Database Management for Db2 Xmanager

book

Article ID: 22570

calendar_today

Updated On:

Products

Database Management for DB2 for z/OS - Administration Suite Database Management for DB2 for z/OS - Performance Suite Database Management for DB2 for z/OS - Recovery Suite Database Management for DB2 for z/OS - SQL Performance Suite Database Management for DB2 for z/OS - Utilities Suite DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS

Issue/Introduction

While starting Database Management for Db2 for z/OS Xmanager task encountering the following message:
GEN0915 Health Checker request failed, RC= 40, RSN= 0, Function=INITIALIZE are generated in log file.

Resolution

RC=40 on the Health Checker initialization request indicates that the Health Checker common service is not installed. If you are using the IBM Health Checker service and are interested in the
integration with Broadcom products (including the Db2 tools), you will also need to install the Health Checker common services delivered with CCS (Common Services).