search cancel

WP processes not starting on Automic server

book

Article ID: 224563

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Automic uc4_data table space was extended

After restarting server processes issue was observed that the WPs are starting / stopping intermittently 

 

Environment

Release :AE

Component :12.3.3

Oracle database 

Resolution

Can see below errors in WP trace logs

06 - 20210922/194934.133 - U00003712 Missing key for accessing variable 'UC_CLIENT_SETTINGS'.
06 - 20210922/194934.133 - U00011829 Client: '9005' - 'TASK_PRIORITY' set to '000000200'.
06 - 20210922/194934.133 - U00003712 Missing key for accessing variable 'UC_CLIENT_SETTINGS'.
06 - 20210922/194934.133 - U00011829 Client: '9005' - 'CALE_LOOK_AHEAD_MAX' set to '000000014'.
06 - 20210922/194934.133 - U00003712 Missing key for accessing variable 'UC_CLIENT_SETTINGS'.

Client 9005 was created some time back for testing and possible corruption of this client based on the above error messages
This client was then deleted using the Automic db client utility 

After this the WP processes were stable