All bar one cluster node of a Process Automation is failing to start, with no error.
Release : 4.3
Component : Process Automation
The root cause was an extra line added to c2o\bin\c2osvcw.conf at the end, which was to introduce a 3rd party jar file that originated from an external monitoring app
Once we commented this out, PAM would start.
Broadcom does not certify any particular monitoring products for use with our applications. If an incompatibility arises, the only thing that will be asked is to remove the attempted inclusion