MUF abends S0C1 in DBSMAPR with LU01677 (CARS2108) applied
search cancel

MUF abends S0C1 in DBSMAPR with LU01677 (CARS2108) applied

book

Article ID: 223493

calendar_today

Updated On:

Products

Datacom/DB Datacom

Issue/Introduction

After having applied CARS2108 maintenance to a Datacom/DB 15.1 MUF,  it keeps abending when running Dataquery SQL query on a DST (Dynamic System Table) table:

CCSR010E DBMUFPR S0C1 at 2193F52A LMOD DBSMAPR CSECT DBSMAPR +00052A DBMUF01 N/A DBMUF01
CCSR021I OWNER = CA Datacom/DB R15.1                                                    
CCSR022I MODULE = DBSMAPR FMID = CABDF10 RMID = SO05738                                 
CCSR060I BREAKING EVENT ADDRESS: 00000000 016A2CCE                                      
CCSR061I PSW: 07042400 80000000 00000000 2193F52A                                       
CCSR062I ILC: 02 INTERRUPT CODE: 01                                                     
CCSR067I COMPLETION CODE S0C1 REASON CODE 00000001      


Environment

Release : 15.1

Component : CA DATACOM/DB

Cause

PTF LU00071 and LU00172 were correctly applied on the SMP/E CABDLOAD.
Something went wrong while copying the modules from that CABDLOAD to the runtime load library used by the MUF experiencing this error, so  modules DBCFMPR and DBSMAPR were not updated on the runtime library:

09.30.45 STC85074  DB00248I - PARM PGMDT=20151231, DBCFMPR  2019/08/05-1256 15.1  SO09510
09.30.46 STC85074  DB00248I - PARM PGMDT=20151231, DBSMAPR  2018/10/30-1248 15.1  SO05738

Resolution

Once the two modules were copied again, the abend no longer occurred. A CAMODID utility can help in checking the RMID of the modules.