When I issue the WLM command, and then select the Workload row (The command issue is WMSYSSUM), I get the message
WLM$011W INTERVAL DATA IS NOT AVAILABLE. TOTAL USED
How can I prevent this message from being issued?
Release : 16.0
Component : SYSVIEW
WLM-INTERVALS parm is still set to the default of 15
Check the MVSDATA Parmlib member. If the WLM-INTERVALS parm is still set to the default of 15, increase the value to 60, put it above the )EOF marker and then recycle the MVSDATA portion of SYSVIEW.
Option : WLM-INTERVALS
Default : 15
Specify the maximum WLM collection intervals.
Valid values:
Minimum - 5
Maximum - 60
Warning message WLM$011W