DAY030 U0999 - WARNING: Apparent symbolic reference MUBWRKSW not resolved
search cancel

DAY030 U0999 - WARNING: Apparent symbolic reference MUBWRKSW not resolved

book

Article ID: 222878

calendar_today

Updated On:

Products

MICS Resource Management

Issue/Introduction

DAY030 is failing with a U0999 error.  SASLOG contains the following error:

WARNING: Apparent symbolic reference MUBWRKSW not resolved
ERROR: A character operand not found
&&&WRK.WRKSW EQ NO

Environment

Release : 14.2

Component : CA MICS BATCH AND OPERATIONS ANALYZER

Resolution

Submit a SMFPGEN in the failing SMF units which will introduce the variable MUBWRKSW.   A change was recently made with regards to the WORK parm but a gen job was not run to define the variable to MICS.  

Additional Information

MUBWRKSW was added as part of SMF7020.  In the checklist for SMF7020, step 9 instructs to run a SMFPGEN job in each SMF unit. 

**********************************************************
* Repeat step(s) 9 for each                                      
* unit database that contains the                              
* CA MICS Batch and Operations Analyzer             
**********************************************************
                                                           
____ 9.   Submit the job in prefix.MICS.CNTL(SMFPGEN).     
          Ensure that there are no error messages in       
          MICSLOG and that the job completes with a        