DFHSM logs error
12.05.32 STC05086 IEC501A M 6410,P99999,SL,COMP,DFHSM,hlq.DFHSM,xxxx.HMIGTAPE.DATASET
12.05.33 STC05086 IEFTMS50 1XX- 08 DFHSM ,jobname ,stepname ,6410,P99999,00001,.xxxxx.HMIGTAPE.DATASET,TMC=data.set.name
12.05.33 STC05086 IEFTMS50 ***** CA 1 ABEND,F1,08 ***** **
12.05.34 STC05086 IEF234E K 6410,P99999,PVT,DFHSM,stepname.DFHSM,xxxxx.HMIGTAPE.DATASET
ARC1001I data.set.name RECALL FAILED, RC=0035,
ARC1001I (CONT.) REAS=0000
ARC1135I ERROR OPENING INPUT DATA SET DURING RECALL/RECOVERY
***
Release : 14.0
Component : CA 1 Tape Management
TMS was temporarily pointing to the wrong TMC.
HSM tape was incorrectly set to SCRATCH status.
To recover the volume you need to:
If HDR1 in the TAPEMAP shows the tape as HSM then you will need to manually update the TMC information.
DSN,
DSN17
EXPDT=PERMANENT
EDMID=HSM (or the EDMID you are using for HSM tapes).
Procedures for TAPEMAP can be found here.