MFES Agent - Cancelling of JOBS in UC4 not possible

book

Article ID: 222302

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

In UC4 the jobs triggered by the MFES Agent cannot be cancelled. The cancel action does not stop the job that continues to run.

Only the command line instruction lsub -c -f<jobnummer> is cancels the jobs actually.

Extracted from the RA MFES Agent Log file

=======================================================

20210510/104841.718 - U00029001 Report '729909562' ended normally.
20210510/105322.785 - U02000005 Job 'AZD_J_RZUCTMPL' with RunID '729909631' started.
20210510/105322.786 - U02000003 Job 'AZD_J_RZUCTMPL' started with RunID '729909631'.
20210510/105322.862 - U00029000 Report '729914152' for file '/opt/uc4/PFIVUC4/agents/mfes/temp/PLOG_OCJLGTZJ.TXT' has been started.
20210510/105401.074 - No such property: prompts for class: MFESJob
20210510/105401.080 - U02001023 Cancel of job 'AZD_J_RZUCTMPL' with RunID '729909631' was successfully initiated.
20210510/105410.293 - U02000148 Start transferring file '/opt/uc4/PFIVUC4/agents/mfes/temp/OCJLGTZJ.TXT' to the User Interface.
20210510/105410.305 - U02000148 Start transferring file '/opt/uc4/PFIVUC4/agents/mfes/temp/OCJLGTZJ.TXT' to the User Interface.
20210510/105410.310 - U02000149 Transfer of file '/opt/uc4/PFIVUC4/agents/mfes/temp/OCJLGTZJ.TXT' to the User Interface completed.
20210510/105410.323 - U02000149 Transfer of file '/opt/uc4/PFIVUC4/agents/mfes/temp/OCJLGTZJ.TXT' to the User Interface completed.
20210510/105410.372 - U02000148 Start transferring file '/opt/uc4/PFIVUC4/agents/mfes/temp/OCJLGTZJ.TXT' to the User Interface.
20210510/105410.385 - U02000149 Transfer of file '/opt/uc4/PFIVUC4/agents/mfes/temp/OCJLGTZJ.TXT' to the User Interface completed.
20210510/105410.382 - U02000148 Start transferring file '/opt/uc4/PFIVUC4/agents/mfes/temp/OCJLGTZJ.TXT' to the User Interface.
20210510/105410.409 - U02000149 Transfer of file '/opt/uc4/PFIVUC4/agents/mfes/temp/OCJLGTZJ.TXT' to the User Interface completed.

=======================================================

 

Cause

This is a bug of the MFES RA agent solution.

Environment

Release : 12.1 Component : AUTOMATION ENGINE

RA MFES Solution  2.2.0

Resolution

This bug is corrected in Version 2.2.3 c of the RA Solution of the MFES Agent.