IEW2326E error occurred when relinking PAM
search cancel

IEW2326E error occurred when relinking PAM

book

Article ID: 221851

calendar_today

Updated On:

Products

Panvalet

Issue/Introduction

Tried to relink the PAM after upgrading Panvalet, but got IEW2326E error.

 IEW2322I 1220  1   INCLUDE PANLMOD(PAM)
 IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN:  INCLUDE PANLMOD(PAM)
 IEW2322I 1220  2   INCLUDE SYSLMOD(xxxxxxxx)
 IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN:  INCLUDE SYSLMOD(xxxxxxxx)
 IEW2322I 1220  3   ENTRY xxxxxxxx
 IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN:  ENTRY xxxxxxxx
 IEW2322I 1220  4   NAME xxxxxxxx(R)
 IEW2326E 1221 THE FOLLOWING INVALID RECORD HAS BEEN SEEN:  NAME xxxxxxxx(R)
 IEW2677S 5130 A VALID ENTRY POINT COULD NOT BE DETERMINED.
 IEW2230S 0414 MODULE HAS NO TEXT.
 IEW2677S 5130 A VALID ENTRY POINT COULD NOT BE DETERMINED.
 IEW2012I 0F09 ALL TEMPNAMES HAVE BEEN USED. THE MODULE CANNOT BE SAVED.
 IEW2008I 0F03 PROCESSING COMPLETED.  RETURN CODE =  12.

Environment

Release : ALL

Component : CA Panvalet

Resolution

This is not a Panvalet error.
Check the start of the INCLUDE PANLMOD(PAM) statement.
The first column needs to be blank.