Not able to connect storage devices.

book

Article ID: 221455

calendar_today

Updated On:

Products

DX Infrastructure Management

Issue/Introduction

Not able to connect storage devices using clariion probe.

This is the error in the log:

Jun 15 06:18:37:082 [Data Collector - 10.165.25.232, clariion] Error occurred while trying to connect: '10.165.25.232'.
Jun 15 06:18:37:082 [Data Collector - 10.165.25.232, clariion] Message : A library or configuration file for NaviSECCli is missing or corrupt. Please use command "security -certificate -cleanup" to fix it. If you still have the same issue, please re-install NaviSECCli.

 

 

Environment

Release : 20.3

Component : UIM - CLARIION

Resolution

Reinstalled naviseccli by choosing options "Do not create Security credentials" and set Security level to low during the install process.