Jobtrac receives message TRAC1075E Abend code S213 in JOBTRAC submit task along with IEC143I 213-70 for PRODJCL
search cancel

Jobtrac receives message TRAC1075E Abend code S213 in JOBTRAC submit task along with IEC143I 213-70 for PRODJCL

book

Article ID: 221279

calendar_today

Updated On:

Products

Jobtrac

Issue/Introduction

JOBTRAC ABEND IN GJTRSUB: S213 U0000 REASON  after IEC143I 213-70 for PRODJCL library when the library
is definded as a PDSE.

Environment

Release : 11.0

Component : JOBTRAC

Resolution

S213 - 70 - OPEN DETECTED A CROSS SYSTEM SHARE CONFLICT FOR THE PDSE indicates that the PDSE defined as the Jobtrac JCL library was already open for update when a second user (Jobtrac) attempted to update it.  The second user receives a S231 RC=70.  In general PDSEs  can be a problem for sharing when a library is being accessed from another system.  This is nothing specific to Jobtrac.  We recommend the use of PDS for the JOBTRAC JCL libraries.
As always, please contact Broadcom support for Jobtrac Job Management if you have further questions.