CCS ZEVENT PROBE - Timestamp on alerts/messages sent to UIM not accurate

book

Article ID: 221134

calendar_today

Updated On:

Products

CA Common Services for z/OS CA OPS/MVS Event Management & Automation CA Unified Infrastructure Management On-Premise (Nimsoft / UIM) CA Unified Infrastructure Management SaaS (Nimsoft / UIM)

Issue/Introduction

Recently implemented the zevent probe to send alerts/messages from mainframe to UIM application.

OPS/MVS is the data producer and CCS Message Service (MS) is responsible for forwarding the data to UIM.

The alerts/messages are successfully being sent to UIM, however they show times that are four hours off.

How do we resolve this?

Environment

Release : 15.0
Component : CCS MESSAGE SERVICE

CA OPS/MVS

UIM - Unified Infrastructure Manager

Resolution

This is working as designed.

The original design for the OPS interface to UIM specifies that timestamps would be presented in ISO-8601 format.  This format was specifically requested by the UIM team.

OPS explicitly converts local time to UTC to satisfy the design spec. Thus it is the responsibility of the data producer (OPS) and data forwarder (MS) to ensure that the dates do not get randomly "mangled" along the path by environmental settings that are hard to control.

The time shown in the "Created" field represents the time (local timezone) that that alert come into UIM.

The time shown in the "Alarm Message" filed represents the time the message occurred in UTC time.