The CA Workload Automation System Agent running on AIX 5.3 does not start due to OS patch level.
search cancel

The CA Workload Automation System Agent running on AIX 5.3 does not start due to OS patch level.

book

Article ID: 22071

calendar_today

Updated On:

Products

Workload Automation Agent

Issue/Introduction

The CA Workload Automation System Agent fails to start with the following error message:

/opt/CA/WA_Agent_R11_3:>exec(): 0509-036 Cannot load program ./cybAgent.bin because of the following errors:
rtld: 0712-001 Symbol __pthread was referenced from module cybAgent.bin(), but a runtime definition of the symbol was not found.

Environment

AIX 5.3

Release: WKLASE99000-11.3-Workload Automation-Agent SE
Component:

Cause

Due to OS patch level.

Resolution

Please upgrade the OS to (Technology Level) TL07 or later.