After reinstall of Automation Point or upgrade from prior release the following message on the AXCREXX window can be shown
4:13:10.049 S2 P2424 T7008 C=NA Sev=E [XCDev::VioShell::OpenConsole] CreateProcess rc=267
Release : 11.7
Component : Automation Point
In this particular case, this issue was caused by locked util.dll file from the prior release.
Reinstall of the Automation Point will be helpful. During uninstall/install process all the pop-up messages should be read. If Wizard notifies that there are any conflicts, they should be addressed before proceeding further. The installation logs showing the info that some files were locked, see below a sample of the log messages.
[29/06/2021 10:52:03] (I) Locked files:
C:\Program Files (x86)\CA\CA Automation Point\Bin\APListen.exe
C:\Program Files (x86)\CA\CA Automation Point\Bin\asoclass.dll
C:\Program Files (x86)\CA\CA Automation Point\Bin\util.dll
[29/06/2021 10:52:03] (I) <BannerHide> [pgConflict.nsh]
[29/06/2021 10:52:08] (W) Continuing the setup process with pending conflicts
This usually indicates that the locked file is in use, to fix it the process or component that using locked file must be stopped.
As a result, a new installation was trying to use util.dll from the prior release, and this fact causing the RC=267 error messages.
After proper reinstallation of the product all works as it should.