Missing message LA549 during Undo SQL generation within Log Analyzer online panels
search cancel

Missing message LA549 during Undo SQL generation within Log Analyzer online panels

book

Article ID: 220261

calendar_today

Updated On:

Products

Log Analyzer for DB2 for z/OS

Issue/Introduction

Attempting to perform a Log Analyzer for Db2 for z/OS (PLA) Undo SQL execution and via online panels
encountering a missing LA549 message:

Message LA549                                   
LA549    message not found in 'ISPMLIB' library.

Resolution

The Log Analyzer LA549 message relates to the following:

LA549I: "Order Output By" field value has been changed to Undo(UN) as no
other value is valid for "Output Format" UndoSQL(U).    


The LA549I message was added by PTF LU00759 and within PTF LU00759 there is a change
to member LA54 in hlq.CDBAMSG0:

++MSG(LA54    ) DISTLIB(ADBAMSG0) SYSLIB(CDBAMSG0)  . 
.
.
LA549    .HELP=LA549I .ALARM=YES                                                
'LA549I: "Order Output By" field value has been changed to Undo(UN) as no  '   +
'other value is valid for "Output Format" UndoSQL(U).'                          


Verify that the hlq.CDBAMSG0 installation dataset was successfully deployed after the latest APPLY of maintenance.