When attempting to run the 14.3 PSP refresh job ESD2104L, the job gets a CC=4 in the #PCHOLD step and flushes all remaining steps.
The SASLOG contains the following warning message:
WARNING: no members found to match @@
Release : 14.3
Component : CA MICS BASE SET
The original valid sharedprefix.MICS.PSP.PC.TEXT data set is no longer available and not recoverable. An empty data set has been allocated to take its place.
To allow the PSP refresh job to be rerun, a member that is named @@BAS must be added to the sharedprefix.MICS.PSP.PC.TEXT data set.
This member must contain one line that contains only 00010000 starting in column 1.