ESD2104L job gets a CC=4 in the #PCHOLD step and flushes all remaining steps
search cancel

ESD2104L job gets a CC=4 in the #PCHOLD step and flushes all remaining steps

book

Article ID: 220117

calendar_today

Updated On:

Products

MICS Resource Management

Issue/Introduction

When attempting to run the 14.3 PSP refresh job ESD2104L,  the job gets a CC=4 in the #PCHOLD step and flushes all remaining steps.  

The SASLOG contains the following warning message:

WARNING:  no members found to match @@ 

 

Environment

Release : 14.3

Component : CA MICS BASE SET

Cause

The original valid sharedprefix.MICS.PSP.PC.TEXT data set is no longer available and not recoverable. An empty data set has been allocated to take its place.

Resolution

To allow the PSP refresh job to be rerun, a member that is named @@BAS must be added to the sharedprefix.MICS.PSP.PC.TEXT data set.
This member must contain one line that contains only 00010000 starting in column 1.

Additional Information

For more information, see the section in the PSP guide on Common installation errors and corrective actions