After performing WCC/EEM installation we found following error message in installation logs
2021-07-09 13:31:16,350 [main] ERROR com.ca.wla.ae.installer.common.service.UnixServiceManager - Problem setting file permissions for init file /logiciel/uwcc/WorkloadAutomationAE/wcc/collectors/WCC_COLLECTOR/scripts//CA-wcc-services
Release : 12
Component : AUTOSYS WORKLOAD AUTOMATION
Following messages are seen right after the error message:
2021-07-09 13:31:16,350 [main] ERROR com.ca.wla.ae.installer.common.service.UnixServiceManager - Problem setting file permissions for init file /opt/CA/WorkloadAutomationAE/wcc/collectors/WCC_COLLECTOR/scripts//CA-wcc-services
2021-07-09 13:31:16,350 [main] INFO com.ca.wla.ae.installer.common.service.UnixServiceManager - Register_Unix_Service - Starting to register service by command : /opt/CA/WorkloadAutomationAE/autosys/csutils/bin/assrvc register --copy --StartInit=35 --StopInit=0126 /etc/init.d//CA-wcc-services
2021-07-09 13:31:16,355 [main] INFO com.ca.wla.ae.installer.util.CommandUtil - Read output stream = Service CA-wcc-services Modified due to:
2021-07-09 13:31:16,355 [main] INFO com.ca.wla.ae.installer.util.CommandUtil - Read output stream = Startup Init Levels changed to match Service File Requirements.
2021-07-09 13:31:16,355 [main] INFO com.ca.wla.ae.installer.util.CommandUtil - Read output stream = Shutdown Init Levels changed to match Service File Requirements.
2021-07-09 13:31:16,357 [main] DEBUG com.ca.wla.ae.installer.util.CommandUtil - RetVal =0
2021-07-09 13:31:16,357 [main] INFO com.ca.wla.ae.installer.common.service.UnixServiceManager - Register_Unix_Service - Service Registered successfully /etc/init.d//CA-wcc-services
Error message can be ignored. WCC is correctly installed and up and running.