Netmaster error BPXP023I fails to initialize USS interface
search cancel

Netmaster error BPXP023I fails to initialize USS interface

book

Article ID: 218972

calendar_today

Updated On:

Products

NetMaster Network Automation

Issue/Introduction

Errors at Netmaster initialization.

BPXP023I THREAD 1D17480000000000, IN PROCESS 66422, WAS 212

TERMINATED BY SIGNAL SIGKILL, SENT FROM THREAD

1D16080000000000, IN PROCESS 66433, UID 2001000252, IN JOB SOLVZ2.

SURF920I STEP START: JOB=SOLVZ3 STEP=STEP1 PGM=BPXPRFC STEP#=001

IEA989I SLIP TRAP ID=XEC6 MATCHED. JOBNAME=SOLVZ3 , ASID=0228.

BPXP023I THREAD 1D18280000000000, IN PROCESS 66430, WAS 215

TERMINATED BY SIGNAL SIGKILL, SENT FROM THREAD

1D17480000000000, IN PROCESS 66426, UID 2001000252, IN JOB SOLVZ3.

IAIN0167 (SOLVZ) parameter group $NM USS failed. Error message follows

 

Environment

Release : 12.2

Component : CA NetMaster Network Automation connecting to USS.

Cause

 IBM mentioned it was the /bin/sh sticky bit that was the issue. 

Resolution

IBM provided APAR AA61517 for the USS environment.

 

Additional Information

SELFTEST UNIX
IPDI5200 TCP/IP Details for H246NM using IBM z/OS Communications Server
IPDI5270 Checking UNIX System Services Interface for SOLVE
BAINWI49 Region user SOLVE has OMVS home /u/solve
N2U701      UNIX Server PID=83953728 State=UP APPLNAME=ABCDEFGH PATH=/tmp/netmaster.unix.022A
IPDI5273    UNIX environment established using USS interface
IPDI5278    Error: UNIX SEND failed, RC/FDBK=8/10, reason=Environment disconnected
IPDI5270 Checking UNIX System Services Interface for M03MCJ
IPDI5273    UNIX environment established using USS interface
IPDI5278    Error: UNIX SEND failed, RC/FDBK=8/10, reason=Environment disconnected
IPDI527Z
IPDI5299 TCP/IP details complete, 2 errors and 0 warnings.