Database Analyzer (IMS Tools) Mainframe Configuration Manager for IMS for z/OS IMS TOOLS - MISC Compress Data Compression (IMS Tools) Database Analyzer for IMS for z/OS Database Copier for IMS for z/OS Database Organizer for IMS for z/OS Mainframe Extended Terminal Manager (IMS Tools) High Performance Recovery for IMS for z/OS Database Organizer (IMS Tools) Mainframe Program Restart Manager for IMS for z/OS Secondary Index Builder for IMS for z/OS Secondary Index for IMS for z/OS DATABASE MANAGEMENT SOLUTIONS FOR IMS FOR Z/OS

Issue/Introduction

Receiving a series of messages:

HPO2010I HPO INITIALIZATION PARAMETER MISSING 
HPO2011I PARAMETER: xxxxxxxxxx
HPO2012I ENTER OPTIONAL PARAMETER VALUE, NULL OR 'EXIT'

Where are these parameters specified, and what must be done to eliminate the messages? 

Resolution

The missing or incorrectly defined parameters are found in the Global Parameter library (CIMTPARM) pointed to by the IDIPARM DD statement.
The parameters (control statements) are defined in a member in the CIMTPARM data set whose name matches the ITK STC name.