OPSMAIN abended with code S028:
*OPS3000S ESTAE LEVEL 1 SYSTEM ABEND CODE=028 TIME=10:31:55 SEQ=0 CPU=00
ASID=0021 (0021 0021)
OPS3006I PSW AT TIME OF ERROR 078C2000 8D56D0FA ILC 0 INTC 11 RSCD
6C000101
*OPS3000S ESTAE LEVEL 1 SYSTEM ABEND CODE=028 TIME=10:31:55 SEQ=0 CPU=00
ASID=0021 (0021 0021)
OPS3007I CURRENT ROUTINE NAME=OPSVALUE ADDRESS=0D567000 OFFSET=000060FA
OPS3006I PSW AT TIME OF ERROR 078C2000 8D56D0FA ILC 0 INTC 11 RSCD
6C000101
OPS3008I GPR 0-3 00000079 00004E6B 19D24100 00C39300
OPS3007I CURRENT ROUTINE NAME=OPSVALUE ADDRESS=0B9A4000 OFFSET=000060FA
OPS3008I GPR 4-7 00000000 00000200 00000002 00018599
OPS3008I GPR 8-11 190EB000 190EB000 0BB1F000 0DA66E84
OPS3008I GPR 0-3 00000079 00004E6B 19D24100 00C39300
OPS3008I GPR 12-15 0D56CFC2 0DA66F10 8D569F3E 0D56CFC2
OPS3008I AR 0-3 00000000 00000002 00000000 00000000
OPS3008I AR 4-7 00000000 00000000 00000000 00000000
OPS3008I AR 8-11 00000000 00000000 00000000 00000000
OPS3008I AR 12-15 00000000 00000000 00000000 00000000
OPS3009I ABENDING LOCATION OPSVALUE+X'60FA'
OPS3009I OPTXSR CALLED BY OPSVALUE+X'2E04'
OPS3009I OPSVALUE CALLED BY OPSQL3+X'C34'
OPS3009I OPSQL3 CALLED BY OPSQCMRU+X'176E'
OPS3009I UNKNOWN CALLED BY SYSTEM+UNKNOWN
OPS3008I GPR 4-7 00000000 00000200 00000002 00018599
OPS3008I GPR 8-11 190EB000 190EB000 0BB1F000 0DA66E84
OPS3008I GPR 12-15 0D56CFC2 0DA66F10 8D569F3E 0D56CFC2
OPS3008I AR 0-3 00000000 00000002 00000000 00000000
OPS3008I AR 4-7 00000000 00000000 00000000 00000000
OPS3008I AR 8-11 00000000 00000000 00000000 00000000
OPS3008I AR 12-15 00000000 00000000 00000000 00000000
OPS3009I ABENDING LOCATION OPSVALUE+X'60FA'
OPS3009I OPTXSR CALLED BY OPSVALUE+X'2E04'
OPS3009I OPSVALUE CALLED BY OPSQL3+X'C34'
OPS3009I OPSQL3 CALLED BY OPSQCMRU+X'176E'
OPS3009I UNKNOWN CALLED BY SYSTEM+UNKNOWN
OPS3259S Product shutdown started due to subtask failure - X'000004'
This is most likely a hardware error. See the link below for the possible causes of this abend S028 according to the IBM documentation:
https://www.ibm.com/docs/en/zos/2.1.0?topic=codes-028
Recommended allocating a new SYSCHK1 dataset and restoring the contents of this file from a backup.