OPSMAIN crash SYSTEM ABEND CODE=028
search cancel

OPSMAIN crash SYSTEM ABEND CODE=028

book

Article ID: 218610

calendar_today

Updated On:

Products

OPS/MVS Event Management & Automation

Issue/Introduction

OPSMAIN abended with code S028:

*OPS3000S ESTAE LEVEL 1 SYSTEM ABEND CODE=028 TIME=10:31:55 SEQ=0 CPU=00

ASID=0021 (0021 0021)

OPS3006I PSW AT TIME OF ERROR 078C2000 8D56D0FA ILC 0 INTC 11 RSCD

6C000101

*OPS3000S ESTAE LEVEL 1 SYSTEM ABEND CODE=028 TIME=10:31:55 SEQ=0 CPU=00

ASID=0021 (0021 0021)

OPS3007I CURRENT ROUTINE NAME=OPSVALUE ADDRESS=0D567000 OFFSET=000060FA

OPS3006I PSW AT TIME OF ERROR 078C2000 8D56D0FA ILC 0 INTC 11 RSCD

6C000101

OPS3008I GPR  0-3  00000079 00004E6B 19D24100 00C39300

OPS3007I CURRENT ROUTINE NAME=OPSVALUE ADDRESS=0B9A4000 OFFSET=000060FA

OPS3008I GPR  4-7  00000000 00000200 00000002 00018599

OPS3008I GPR  8-11 190EB000 190EB000 0BB1F000 0DA66E84

OPS3008I GPR  0-3  00000079 00004E6B 19D24100 00C39300

OPS3008I GPR 12-15 0D56CFC2 0DA66F10 8D569F3E 0D56CFC2

OPS3008I AR  0-3  00000000 00000002 00000000 00000000

OPS3008I AR  4-7  00000000 00000000 00000000 00000000

OPS3008I AR  8-11 00000000 00000000 00000000 00000000

OPS3008I AR 12-15 00000000 00000000 00000000 00000000

OPS3009I ABENDING LOCATION  OPSVALUE+X'60FA'

OPS3009I OPTXSR   CALLED BY OPSVALUE+X'2E04'

OPS3009I OPSVALUE CALLED BY OPSQL3+X'C34'

OPS3009I OPSQL3   CALLED BY OPSQCMRU+X'176E'

OPS3009I UNKNOWN  CALLED BY SYSTEM+UNKNOWN

OPS3008I GPR  4-7  00000000 00000200 00000002 00018599

OPS3008I GPR  8-11 190EB000 190EB000 0BB1F000 0DA66E84

OPS3008I GPR 12-15 0D56CFC2 0DA66F10 8D569F3E 0D56CFC2

OPS3008I AR  0-3  00000000 00000002 00000000 00000000

OPS3008I AR  4-7  00000000 00000000 00000000 00000000

OPS3008I AR  8-11 00000000 00000000 00000000 00000000

OPS3008I AR 12-15 00000000 00000000 00000000 00000000

OPS3009I ABENDING LOCATION  OPSVALUE+X'60FA'

OPS3009I OPTXSR   CALLED BY OPSVALUE+X'2E04'

OPS3009I OPSVALUE CALLED BY OPSQL3+X'C34'

OPS3009I OPSQL3   CALLED BY OPSQCMRU+X'176E'

OPS3009I UNKNOWN  CALLED BY SYSTEM+UNKNOWN

OPS3259S Product shutdown started due to subtask failure - X'000004'

 

 

 

 

 

Environment

Release : 13.5

Component : OPS/MVS

Resolution

This is most likely a hardware error. See the link below for the possible causes of this abend S028 according to the IBM documentation:

https://www.ibm.com/docs/en/zos/2.1.0?topic=codes-028

Recommended allocating a new SYSCHK1 dataset and restoring the contents of this file from a backup.