*MASTER* took an SVC DUMP
search cancel

*MASTER* took an SVC DUMP

book

Article ID: 218557

calendar_today

Updated On:

Products

OPS/MVS Event Management & Automation

Issue/Introduction

Review of the dump shows the abend0C3 (S0C3) is in OPSMAIN code OPRXCMRU.

CNZS1XIT is a routine in WTO processing that passes control to subsystems that are looking for messages.

Systrace shows the abend occurred during processing of WTO.

OPS got control via a PC, routine OPPCSSRU, shortly after PGM 003 was encountered.

 

     

 

Environment

Release : 13.5 14.0

Component : OPS/MVS

Resolution

Related OPS/MVS solutions:

 Release    PTF 
13.5      LU01174 https://support.broadcom.com/download-center/solution-detail.html?aparNo=LU01174&os=z%2FOS

14.0      LU00913 https://support.broadcom.com/download-center/solution-detail.html?aparNo=LU00913&os=z%2FOS