Apply SYSVIEW PTF LU00548 GIM35901I ERROR HOLD CL00548 WAS NOT RESOLVED
search cancel

Apply SYSVIEW PTF LU00548 GIM35901I ERROR HOLD CL00548 WAS NOT RESOLVED

book

Article ID: 217683

calendar_today

Updated On:

Products

SYSVIEW Performance Management

Issue/Introduction

Applying the CARS PTFs and APPLY CHECK fails with many GIM30206E and GIM35907I errors.

GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD LU00548. HOLD REASON IDS WERE NOT RESOLVED.                    
GIM35949I    ERROR HOLD AL00548 WAS NOT RESOLVED. SYSMOD LU00742 WOULD HAVE SUPERSEDED AL00548, BUT HAS FAILED.
GIM35949I    ERROR HOLD BL00548 WAS NOT RESOLVED. SYSMOD LU01138 WOULD HAVE SUPERSEDED BL00548, BUT HAS FAILED.
GIM35901I    ERROR HOLD CL00548 WAS NOT RESOLVED.                                                              

GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD LU00517. HOLD REASON IDS WERE NOT RESOLVED.                    
GIM35907I    PREREQUISITE SYSMOD LU00548 FAILED.                                                               
                                                                                                               
GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD LU00527. HOLD REASON IDS WERE NOT RESOLVED.                    
GIM35907I    PREREQUISITE SYSMOD LU00548 FAILED.                                                   

Environment

Release : 16.0

Component : SYSVIEW

Cause

PTF LU00548 is marked as HOLD with REASON(CL00548) in the HOLDDATA.

++HOLD(LU00548) ERROR FMID(CNM4G00)                              
 REASON(CL00548) DATE(21167) CLASS(PE)                           
 COMMENT(                                                        
                                                                 
   PROBLEM SYSVW-14032:  PROCINFO XSDATA DISPLAYING INVALID      
   DATA                                                          
 SMRTDATA(                                                       
  SYMP(FUL)                                                      
       )).    

Resolution

LU00548 is PE and is corrected by PTFs LU00742 and LU01138

Download and RECEIVE these 2 PTFs.

No fix is available yet for the third hold reason CL00548.

To apply the PTF add the HOLDERROR(reason id) option to the BYPASS in the APPLY CHECK or APPLY:

APPLY
  CHECK               /*** Remove to apply all PTFs.    ***/
   SOURCEID(CAR*)     /*** Used to apply CA RS  ***/
GROUPEXTEND(NOAPARS NOUSERMODS)
BYPASS(HOLDSYSTEM,HOLDERROR(CL00548)) .

Additional Information

HOLDERROR CL00548 is now corrected with PTF LU01773.
Please refer new HOLDDATA file packaged with LU00548.

++HOLD(LU00548) ERROR FMID(CNM4G00)
 REASON(CL00548) DATE(21167) CLASS(PE)
 COMMENT(

   PROBLEM SYSVW-14032:  PROCINFO XSDATA DISPLAYING INVALID
   DATA
 SMRTDATA(CHGDT(210621)   FIX(LU01773)
  SYMP(FUL)
       )).