DC088029 message during IDMS startup
search cancel

DC088029 message during IDMS startup

book

Article ID: 21744

calendar_today

Updated On:

Products

IDMS IDMS - Database

Issue/Introduction

After adding a TCP/IP LINE in SYSGEN, during the subsequent startup the following message appears in the joblog :

                DC088029 V1 Warning: TCP/IP support enabled for compatibility with r16.

What does this mean ?

Environment

Release: All supported releases
Component: IDMS (TCPIP support).

Cause

Prior to r17.0, the TCP/IP attributes of an IDMS CV were defined in the TCP/IP LINE and listener PTERM definitions.

As of r17.0 and higher releases, they should be defined in a new SYSGEN entity called the TCP/IP statement.

The upgrade process to IDMS releases 18.0/18.5 and 19.0 does not automatically create such a TCP/IP SYSGEN statement - it must be done manually.

Until this is done, during startup of an 18.0, 18.5 and 19.0 CV, the DC088029 informational message is issued at startup to indicate that the pre r17.0 method of defining TCP/IP attributes has been used.

Resolution

Add a TCP/IP statement to the SYSGEN.