search cancel

Edit Alias is missing after updating to 20.3.3 June update.

book

Article ID: 216743

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

The 20.3.3 June update introduces a new ACL 'OC Device Update' and this has to be added for the Edit Alias to show up. 

Environment

Release : 20.3

Component : UIM Operator Console - Inventory

Resolution

This is documented in ump_operatorconsole-2.1.0-HF3.txt. 
Configuration:
==============
1. The new permission "OC Device Update" in ACL decides which users can access "Modify Alias" functionality of a Device. 
2. On the primary hub, check the file /Nimsoft/probes/service/distsrv/base_acls.cfg and make sure it has the ACLs below. 
You can manually add them by copy pasting the below. Save the file. 
======
   <OC Device Update>
      name = OC Device Update
      desc = Allow users to update device information
      access = admin
      type = OperatorConsole
   apply_to_existing_acls = Superuser,Administrator,Operator
   </OC Device Update>
======

3. In Infrastructure Manager/Admin Console, navigate the distsrv probe on the primary hub.
4. With the distsrv probe selected, press "Ctrl-P" the probe Utility (pu) should appear.
5. In the probe commandset, select callback set_acl_init with the parameter value "base_acls.cfg". The callback updates the security.cfg with the ACLs, it will not delete any ACLs, nor change any ACLs.
6. In Account Admin section of Operator Console, select the "OC Device Update" permission for all applicable ACLs. It is enabled by default for Superuser, Administrator & Operator.
7. In infrastructure manager, open Security -> Manage Access Control List. Check to make sure the applicable ACL has "OC Device Update" selected.

Note: step 4 is modified since there have been reports of the callback not working when done via AC. 
Original step 4:
4. With the distsrv probe selected, press "Ctrl-P" the probe Utility (pu) should appear or launch Probe Utility from AdminConsole.