HSAL6010A
These are messages I have never seen before, they due to an IPL and the messages are from console
and the system log.
15 STC58010 00000080 *HSAL6010A OPSMAIN/APL/MAI2; INTERVENTION REQUIRED; BEYOND AUTOMATION
15 STC47991 00000080 *HSAL6010A OPSMAIN/APL/MAI2; INTERVENTION REQUIRED; BEYOND AUTOMATION
15 STC13910 00000080 *HSAL6010A OPSMAIN/APL/MAI2; INTERVENTION REQUIRED; BEYOND AUTOMATION
15 STC97124 00000080 *HSAL6010A OPSMAIN/APL/MAI2; INTERVENTION REQUIRED; BEYOND AUTOMATION
19 STC62275 00000080 *HSAL6010A OPSMAIN/APL/MAI2; INTERVENTION REQUIRED; BEYOND AUTOMATION
05 STC97124 00000080 AOF776I CONNECTION FROM DOMAIN NVMMB MBI2 REJECTED AT DOMAIN NVMMV 127
127 00000080 - INBOUND GATOPER GATNVMMB COULD NOT BE SET UP
27:45.84 STC13910 00000080 AOF776I CONNECTION FROM DOMAIN NVMMD MDI3 REJECTED AT DOMAIN NVMMV 024
024 00000080 - INBOUND GATOPER GATNVMMD COULD NOT BE SET UP
11 STC62275 00000080 AOF571I 13:55:09 : OPSMAIN SUBSYSTEM STATUS FOR JOB OPSMA
715 00000080 STARTED2 - EXTERNAL RECOVERY APPEARS TO HAVE STALLED
STC47991 00000080 AOF776I CONNECTION FROM DOMAIN NVMMD MDI3 REJECTED AT DOMAIN NVMMV 813
813 00000080 - INBOUND GATOPER GATNVMMD COULD NOT BE SET UP
5.53 STC58010 00000080 AOF776I CONNECTION FROM DOMAIN NVMML MLI3 REJECTED AT DOMAIN NVMMV 357
357 00000080 - INBOUND GATOPER GATNVMML COULD NOT BE SET UP
What are these and how to fix this?
Release : 13.5
Component : OPS/MVS
The messages are generated by SA z/OS and resolution should be pursued with IBM.
An attempt to establish a cross-domain gateway has failed.
The variable domain_id_1 shows the domain attempting to connect.The variable sdfroot_name shows the system attempting to connect.The variable domain_id_2 shows the domain rejecting the connection.The variable reason shows the reason for rejecting the connection.The connection will be tried again at gateway monitor time.
None.
The gateway definitions in the automation control file on either or both domains need correction to ensure compatibility.
40, 43.
HSAL6010A resource; INTERVENTION REQUIRED; BEYOND AUTOMATION
A problem with the resource has been detected that automation cannot handle.
Automation for the resource is stopped.
Fix the problem or notify your system programmer.
Try to fix the problem.
80, 81.