Issue/Introduction

Process of upgrading from 11.3 to 12.1

and getting a error for CCI errors.  Not using using CCI.

Environment

Release : 11.3

Release :  12.0

Release : 12.1

Component : CA  7

Cause

CCI Terminal not found when running AL2DCB10.

Resolution

 

The JS010 step does not need to run.  It only issue a XREF (cross reference command) to show errors.
The JS020 which is the DBVR (database verification) will show errors. Plus you will run the 
validation job later. So, there is no impact to not running this step. When you go to upgrade production and have a problem with 
the CCI interface, you can skip this step only.  Also, if you are not using the CCI Interface with CCI Terminals, this is also a reason for not running this step.