The following abend occurred:
PDT0732 DETECTOR TERM CLEANUP COMPLETE DB2=DSNH
IEC161I 056-084,BWZXMAN,BWZXMAN,SYS00058,,, 182
IEC161I SYS3.CADB2.SYSD.DSNH20CD.DTRW002.DSNH,
IEC161I SYS3.CADB2.SYSD.DSNH20CD.DTRW002.DSNH.DATA,CATALOGO.SYS3
IEC161I 062-086,BWZXMAN,BWZXMAN,SYS00058,,, 183
IEC161I SYS3.CADB2.SYSD.DSNH20CD.DTRW002.DSNH,
IEC161I SYS3.CADB2.SYSD.DSNH20CD.DTRW002.DSNH.DATA,CATALOGO.SYS3
PDT0170 DETECTOR COLLECTION INTERVAL END TIME=14:13 INTERVAL=01:00 DB2=DSNH VCAT
DATASTORE=DSNH20CD REL=20
IEA705I ERROR DURING FREEMAIN SYS CODE = 378-14 BWZXMAN BWZXMAN 40
IEA705I 00F33E80 00ABC5B0 00ABC5B0 00000300 0000FFE0 1C2FE020
IEA995I SYMPTOM DUMP OUTPUT 194
SYSTEM COMPLETION CODE=378 REASON CODE=00000014
TIME=14.13.43 SEQ=36342 CPU=0000 ASID=0170
PSW AT TIME OF ERROR 070C1000 813271C0 ILC 2 INTC 0D
NO ACTIVE MODULE FOUND
NAME=UNKNOWN
DATA AT PSW 013271BA - 00181610 0A0D18CE 18FB180C
AR/GR 0: 00000000/00000000_84000000 1: 00000000/00000000_84378000
2: 00000000/00000000_0000FFE0 3: 40000000/00000050_00000003
4: 00000000/00000000_00ABC5B0 5: 00000000/00000000_00AB02B8
6: 00000000/00000000_81668BA0 7: 00000000/00000000_00F33E80
8: 00000000/00000000_00000000 9: 00000000/00000000_0000FFE0
A: 00000000/00000000_1C2FE020 B: 00000000/00000000_7F461430
C: 00000000/00000000_00004000 D: 00000000/00000000_1C1CC12C
E: 00000000/00000000_1C234A0A F: 00000000/00000000_00000014
END OF SYMPTOM DUMP BWZXMAN is the XMANAGER Name
Release : 20.0
Component : CA Detector for DB2 for z/OS
The dump and abend were caused by the CA-DB2 Tools Health Checker using old Detector libraries. Providing the correct libraries resolved the problem.