'CDZ' for IBM Sterling Connect:Direct is specified on a DATA SOURCE statement in prefix.PARMS(SNTOPS), but the file does not
get created in the database.
BAS11002W messages in the CYCLGEN MICSLOG indicate all cycles for the CDZCCT file are set to 0.
BAS11001I FILE SNT CDZCCT 07 07 09 06 00 00 055 024
BAS11002W DETAIL CYCLE SET TO 0
BAS11002W DAYS CYCLE SET TO 0
BAS11002W WEEKS CYCLE SET TO 0
BAS11002W MONTHS CYCLE SET TO 0
BAS11005W WEEKS HISTORY LIMIT SET TO 0
BAS11005W MONTHS HISTORY LIMIT SET TO 0
Release : 14.2
Component : CA MICS SNA NETWORK ANALYZER
Make sure the 7th parameter in the OPTIONS statement in sharedprefix.MICS.GENLIB(SNTGENIN) is set to CDZ, and the FILE CCT statement contains Y's in the desired timespans.
1. Then run the sharedprefix.MICS.CNTL(SNTCGEN).
2. Execute the Unit level steps found in
sharedprefix.MICS.PSP.PC.TEXT(@SNT6740).