4 LPARS in MIM complex(SYS1,SYS2,SYS3,SYS4)
SYS1 & SYS2 are in PROD sysplex
SYS3 & SYS4 are in TEST sysplex.
Recently we used FDRPAS to move all our DASD storage to different DASD raids and unit addresses.
IPLed the SYS3 & SYS4 LPARS
The D FILES command in SYS3 & SYS4 show the correct unit address
However, the same command in SYS1 & SYS2 continue to show the old unit addresses that no longer exist
SYS1 RESPONSES ------------------------------------------------
MIM0067I Command DISPLAY 869
MIM0102I Control File Display:
File Unit Status Volser Data Set
00 61FD BACKUP VMIMS1 MIM.MII.CF00
01 62F9 USABLE VMIMS2 MIM.MII.CF01
MIM0104I Checkpoint File Display:
File Unit Status Volser Data Set
00 639C IN-USE LIBSPV MIM.SYS1.MII.CKPT00
01 6281 USABLE LIBSPE MIM.SYS1.MII.CKPT01
SYS2 RESPONSES ------------------------------------------------
MIM0067I Command DISPLAY 744
MIM0102I Control File Display:
File Unit Status Volser Data Set
00 61FD BACKUP VMIMS1 MIM.MII.CF00
01 62F9 USABLE VMIMS2 MIM.MII.CF01
MIM0104I Checkpoint File Display:
File Unit Status Volser Data Set
00 639D IN-USE LIBSPW MIM.SYS2.MII.CKPT00
01 618E USABLE LIBSPH MIM.SYS2.MII.CKPT01
SYS3 RESPONSES -----------------------------------------
MIM0067I Command DISPLAY 850
MIM0102I Control File Display:
File Unit Status Volser Data Set
00 1223 BACKUP VMIMS1 MIM.MII.CF00
01 1315 USABLE VMIMS2 MIM.MII.CF01
MIM0104I Checkpoint File Display:
File Unit Status Volser Data Set
00 11A8 IN-USE LIBSPH MIM.SYS3.MII.CKPT00
01 13B1 USABLE LIBSPW MIM.SYS3.MII.CKPT01
SYS4 RESPONSES -----------------------------------------
MIM0067I Command DISPLAY 421
MIM0102I Control File Display:
File Unit Status Volser Data Set
00 1223 BACKUP VMIMS1 MIM.MII.CF00
01 1315 USABLE VMIMS2 MIM.MII.CF01
MIM0104I Checkpoint File Display:
File Unit Status Volser Data Set
00 115C IN-USE LIBSPC MIM.SYS4.MII.CKPT00
01 115C USABLE LIBSPC MIM.SYS4.MII.CKPT01
Release : 12.5
Component : MIM
Unknown
PTF LU06098 has been written to correct this.
Until the fix is applied, the invalid unit reference is only witnessed with a DISPLAY FILES command and is not impacting functionality.
WORKAROUND:
An IPL of the system corrects the display.
The correct unit reference will be witnessed with a DISPLAY IO command.