Description:
When entering option 199 to display more fields in CA Detector field descriptions
help panel PDTHCOL2:
PDTHCOL2 -------- DETECTOR Common Display Fields - Help -------- COMMAND ===> 199
To see a field description, enter the corresponding number in the command line. To review descriptions sequentially, just
press <Enter> without selecting a number.
51 GLOCKREQ 64 PFAILBUF 77 OWIOWCNT 90 SMSG_WTIME 52 GCHNGREQ 65 PFAILENC 78 SERV_WTIME 91 SMSGWCNT 53 GUNLKREQ 66 SPPLANNED 79 SERVWCNT 92 GLOCK_WTIME 54 GIRLMSUS 67 SPFAILBUF 80 ARCH_WTIME 93 GLOCKWCNT 55 GXESSUS 68 SPFAILCNO 81 ARCHWCNT 94 LOG_WTIME 56 FALSESUS 69 SPFAILRRRS 82 PLATCH_WTIME 95 LOGWCNT 57 GLOCKFAIL 70 IO_WTIME 83 PLATCHWCNT 96 LOB_WTIME 58 PMAXDEG 71 IOWCNT 84 DRAIN_WTIME 97 LOBWCNT 59 PGROUPS 72 LOCK_WTIME 85 DRAINWCNT 98 OCS_WTIME 60 PPLANNED 73 LOCKWCNT 86 CLAIM_WTIME 99 OCSWCNT 61 PREDUCED 74 ORIO_WTIME 87 CLAIMWCNT 100 SLS_WTIME 62 PFAILCUR 75 ORIOWCNT 88 ARCRD_WTIME 63 PFAILSRT 76 OWIO_WTIME 89 ARCRDWCNT 199 More fields PF3 = Exit Help PF7 = Menu
The following ISPF panel error appears:
ISPF Dialog Error Command ===>
******************************************** * ISPP121 * * Panel 'PDTHCOL3' error * Panel definition too large, greater than screen size. * * Panel line where error was detected: * + * * Enter HELP command for further information regarding this error. * Press ENTER key to terminate the dialog.
Solution:
This error was encountered using a terminal IBM 3278-2 emulator (mod 2). Change the emulator to 3278-3 (mod 3) or 3278-4 (mod 4) and the help panel will display without any problem.