CICSOGR Messages GSVX271I, IXG231I, GSV2808I, GSVX554E, GSVX571I
search cancel

CICSOGR Messages GSVX271I, IXG231I, GSV2808I, GSVX554E, GSVX571I

book

Article ID: 214059

calendar_today

Updated On:

Products

SYSVIEW Performance Management

Issue/Introduction

The Following message occurs at startup.

GSVX271I (CICSLOGR) CICSLOGR connected to log stream GSVX110.XLOG.xxxxtype CICSLOGR.XLOG   
IXG231I IXGCONN REQUEST=CONNECT TO LOG STREAM NOT.DEFINED DID NOT  399                      
SUCCEED FOR JOB SYSVIEW.  RETURN CODE: 00000008  REASON CODE: 0000080B                      
DIAG1: 00000000  DIAG2: 00000000  DIAG3: 00000000  DIAG4: 00000000                          
GSV2808I (CICSLOGR) Specified log stream name not defined in the LOGR policy.               
GSVX554E (CICSLOGR) IXGCONN CONNECT failed, log stream name not defined                     
GSVX571I (CICSLOGR) CICSLOGR task initialization complete                                   

I have looked at all the logstream definitions in parmlib member CICSLOGR and they are defined.  I do not find a logstream named 'not.defined'. 

Environment

Release : 16.0

Component : SYSVIEW

Resolution

This error was caused by a missing definition for the EITL logstream. If the EITL logstream isn't required, set the Logstream definition to NONE in the CICSLOGR parmlib member. Otherwise, define the EITL logstream and put the defined name into the CICSLOGR and LGLOOKUP member.  

 

 

Additional Information

For more information:

Assign Values for Variables

Install Products Using z/OSMF

CICS Data Logger Subtask Setup

MVS Log Streams Usage

LGLOOKUP

CICSLOGR