Whentryin to start cleanup using COMMNDxx member we get the following.
ETCL108E Initialization failed
IEFACTRT ACF2CLN STEP# 1 STEP: AT5 CC: 0008
IEF170I 1 ACF2CLN IEFACTRT ACF2CLN STEP# 1 STEP: AT5 CC:
IEF404I ACF2CLN - ENDED - TIME=07.29.24
IEF196I IEF142I ACF2CLN ACF2CLN - STEP WAS EXECUTED - COND CODE 0008
Here is the order in COMMNDxx
COM='S ACF2,PARM='SYSID(SYSB),COMMAND(S OPSMVS,MAINPRM=IPL,SUB=MSTR)''
COM='S ACF2CLN,SUB=MSTR'
COM='S CA90S,SUB=MSTR'
COM='SETCON MN,SESS=ON,T=ON'
Release : 12.1
Component : CA Cleanup for ACF2
To start CA Cleanup from COMMNDxx requires that CA ACF2 be started before cleanup starts.
Initialization message ACF8A900 ACF2 INITIALIZATION COMPLETE - CA ACF2 REL 16 must have been issued.
This would mean that CA ACF2 must start from CAISEC00 and CAIACF00 if CA Cleanup
needs to start from COMMNDxx.