Issue/Introduction

For some viptela devices, the viptela vpn VC has a higher priority that the high speed interface VC.

Interfaces using the viptela VC’s don’t populate the values in the ipaddress/subnet column.

Viptela VPN Interface (Port) VC

 

Interfaces discovered using the mib2 VC do show that info.

 

 

Environment

Release : 20.2

Component : CA Performance Center

Cause

We use values from mib2 to get the ipaddress ofr an interface, then we align those values with the ifindex from mib2.

If the match we populate the column.

Resolution

Since the viptela MIB uses a different ifindex than the mib2 MIB, the ifindex will never align.

This field will not be populated.