Multiple Autosys jobs are in Running State
search cancel

Multiple Autosys jobs are in Running State

book

Article ID: 212810

calendar_today

Updated On:

Products

Autosys Workload Automation

Issue/Introduction

The jobs that are executed will completed but still show in a running status (in autosys and WCC as well)

Below is the error message you  may find in event demon logs.

CAUAJM_W_10575 Network performance warning: Detected an out of sequence, repeated message for job [4668.3905940.1] from agent [WA_AGENT localhost].

Environment

Release : 11.3.6 

Component : WORKLOAD CONTROL CENTER

Resolution

Make sure to take a downtime if its happening on production server. And follow below resolution steps.

1.Perform Cold start on Agent.

2. Once cold start is completed restart all the jobs manually running on this Agent.

Additional Information

How to cold start a Workload Automation Agent
https://knowledge.broadcom.com/external/article/43249/how-to-cold-start-a-workload-automation.html

How to cold start CA Workload Automation (CA WA) and what happens after cold start?
https://knowledge.broadcom.com/external/article/50942/how-to-cold-start-ca-workload-automation.html