Installing Sysview 16.0, the first installation job (INST0001) is causing issues when the datasets including the SMP/E datasets need to be allocated on NONSMS volumes.
It seems that even if SMS=NO is specified into the GSVINS installation macro, SMS ACS routines are getting invoked during the allocation of the datasets and the job fails.
Release : 16.0
Component : SYSVIEW
As verified, the ACS routines are always involved assigning STORCLAS=STANDARD when SMS=NO.
In order to assign STORCLAS=NONSMS and the correct VOLUME, in INSTALL job the following setting need to be specified:
SMS=YES
STOCLAS=NONSMS
SMSVOL=vvvvvv
where vvvvvv is the volume for the datasets allocation
Moreover, VOLUME(vvvvvv) (volume for the SMP/E datasets allocation) needs to be added to the IDCAMS input INST0001 installation job.