MTCA - Message Server on other LPARs fail to reconnect to ServerHub following IPL
search cancel

MTCA - Message Server on other LPARs fail to reconnect to ServerHub following IPL

book

Article ID: 212323

calendar_today

Updated On:

Products

COMMON SERVICES FOR Z/OS OPS/MVS Event Management & Automation Mainframe Operational Intelligence WatchTower WatchTower Platform

Issue/Introduction

Running a single Message Server HUB running on LPAR SYSA and multiple Message Service servers running on various other connected LPARS.

When SYSA is IPL'd, some of the remote LPARS are not able to "re-connect". The external symptom is that not all "servers" are appearing on the MTC-A Web interface.

Environment

Release : 15.0
Component : CCS MESSAGE SERVICE

Resolution

PTF LU02071

CCS MESSAGE SERVICE CUMULATIVE MAINTENANCE SHIPMENT - 1.9.8       
                                                                  
PROBLEM DESCRIPTION:                                              
Updates to ops-admin-adapter to fix issue where some LPARs fail to
reconnect to server hub following an IPL                          
                                                                  
SYMPTOMS:                                                         
Users of MTCA fail to see some LPARS reappear following an outage 
of the MSS hub