Running in New Function mode, a return-code of 00 is given, in spite of this "severe error":

+++PSI/DBCS SUBSYSTEM ERROR+++                    
+++LOCATION:                                      
PSIDBSYS.GETDBC                                   
+++REASON:                                        
PSI/DBCS SUBSYSTEM HAS NOT BEEN ACTIVATED.        
+++PSIDB RC OF 134.                               
ERROR IS SEVERE. PROGRAM TERMINATED.              

How may the above errors be fixed?

 

Environment

Easytrieve Report Generator, release 11.6

Resolution

PTF: LU00195 

SUMCTL TAG FAILS IF SO05162 IS INSTALLED WITH DBCS DISABLED
Apar No - LU00195

 
PROBLEM DESCRIPTION:
The program compilation fails if SUMCTL TAG statement is used and
SO05162 was installed with DBCS subsystem disabled.
 
SYMPTOMS:
The program compilation fails with the following error:
   +++PSI/DBCS SUBSYSTEM ERROR+++
   +++LOCATION:
   PSIDBSYS.GETDBC
   +++REASON:
   PSI/DBCS SUBSYSTEM HAS NOT BEEN ACTIVATED.
   +++PSIDB RC OF 134.
   ERROR IS SEVERE. PROGRAM TERMINATED.