CA 7 message CA-7.NUC 7 and CA-7.NUC 8 for module CAL2LVLS
search cancel

CA 7 message CA-7.NUC 7 and CA-7.NUC 8 for module CAL2LVLS

book

Article ID: 211279

calendar_today

Updated On:

Products

CA 7 Workload Automation

Issue/Introduction

With the last CA7 12.1 maintenance, the following two the new messages are added :  

CA-7.NUC 7

- CD level set module load failed, name=CAL2LVLS

Reason:

The load module CAL2LVLS could not be loaded.

Action:

Check to ensure that the CAL2LVLS load module is in the normal load module search.

 

CA-7.NUC 8

- CD level set eyecatcher error: xxxx

Reason:

The load module CAL2LVLS did not have the expected data area eyecatcher xxxx.

Action:

Check to ensure that the CAL2LVLS load module is valid

 

Any additional detail about this new topic?

 

Environment

Release : 12.1

Component : CA-7

Resolution

These new messages have been introduced with CA7 PTFs 

SO15328 - CONTINUOUS DELIVERY LEVEL SET 12.1.01 FOR CA 7

SO15040 - CONTINUOUS DELIVERY LEVEL SET 12.1.00 FOR CA 7

In fact , CA7 is one of the MF products that adopted the Continuous Delivery Strategy for maintenance activity and details can be found at the link below: 

Continuous Delivery Strategy

section 'Continuous Delivery Strategy' 

and 'Mainframe Products Using Continuous Delivery'.

So the above PTFs will introduce a sort of new genlevel of the product that is defined as a 'LEVEL SET' and module CAL2LVLS will store this Level Set value : 

- PTF SO15040 adds the new module CAS2LVLS that will starts with LEVEL SET 00 :

'CONTINUOUS DELIVERY LEVEL SET 12.1.00 FOR CA 7

- PTF  SO15328 contains all the GA PTFs included in LEVEL SET 01 and will also update module CAL2LVLS to LEVEL SET 01:

'CONTINUOUS DELIVERY LEVEL SET 12.1.01 FOR CA 7'

The new messages will certify that module CAL2LVLS is present in the CA 7 load library with the correct LEVEL SET, according to the maintenance level in place.

Each future GA PTF published for the Continuous Delivery of a new LEVEL SET, will contain a ++HOLD ACTION looking like the following: 

            
                      *********************************                               
                      * STEPS    TO    PERFORM *                               
                      *********************************                               
                                                                               
You should review all Hold data for each PTF included in this                  