Different results using FIND command on two SYSVIEW regions
search cancel

Different results using FIND command on two SYSVIEW regions

book

Article ID: 210698

calendar_today

Updated On:

Products

SYSVIEW Performance Management

Issue/Introduction

Running Sysview on multiple systems, you can verify a different behavior using FIND command ( e.g. on SYSLOG output command).

For example:

On the first system, executing FIND command, Sysview returns message :  FIND011I Found next chars 'xxxx'  and the matching string is highlighted.

On the second system instead,  Sysview returns message :  FIND011I Found next chars 'xxxx' col NN   and no string is highlighted.

 

Environment

Release : 16.0

Component : SYSVIEW

Cause

The SET keyword FINDTop is set differently in the 2 systems: in fact, on the first system FINDTop  is set to NO, while on the second is set to YES

Resolution

FINDH and/or TOPICS