OPS/MVS: Limit to the length of a message that a rule can respond to
search cancel

OPS/MVS: Limit to the length of a message that a rule can respond to

book

Article ID: 210444

calendar_today

Updated On:

Products

OPS/MVS Event Management & Automation

Issue/Introduction

Is there a limitation on the length of the message you can use to test a rule?  The HZR020I runtime diagnostics message is quite large, and the panel in 2.1 looks like it only supports two lines for a message.

Environment

  • OPS/MVS

Resolution

There is not a limit.  This message is a multi-line WTO (MLWTO) so it is composed of several lines. To test the current rule on the AOF test environment panel (2.1) enter this message:

HZR0200I   TYPES: LOOP:1

This should trigger the rule in the test environment in the same way it will be triggered when the actual message appears.