Issue/Introduction

I think the RMF7125 update might have affected this reporting job I have. Do you know if this variable was removed or discontinued? 

The job is setting HARCFR01 and this variable is not found. 

ERROR: Variable CFRSTYPE not found.                                 
NOTE: The SAS System stopped processing this step because of errors.
NOTE: The PROCEDURE PRINT used 0.09 CPU seconds.                    
                                               

Environment

Release : 14.2

Component : CA MICS HARDWARE AND SCP ANALYZER

Resolution

Update the report code to print CFYSTYPE instead of CFRSTYPE.

Prior to RMF7125, we had CFRSTYPE in the HARCFR file to identify the structure type.  With RMF7125, we added a couple of new files (CFM  for Storage Class Memory and CFN for Asynchronous Duplexed structures) and CFRSTYPE was obsoleted.  A common data element CFYSTYPE was added to many of the facility related files that contains the "structure type". 

 

Additional Information

CFYSTYPE