After importing EEM policies, Error: E190098 during validation of a server configuration of WCC
search cancel

After importing EEM policies, Error: E190098 during validation of a server configuration of WCC

book

Article ID: 210081

calendar_today

Updated On:

Products

CA Workload Automation AE - Scheduler (AutoSys)

Issue/Introduction

EEM Policies were imported into a new instance of EEM successfully. However, validation of AutoSys server in WCC gives below error:

Error: E190098 ABCXXX (web services validation) - A connection exception was encountered: https://ABCXXX:9443/AEWS returned status 403.
Confirmation: I190220 The CSAM is configured properly for the ports 9000, 49152.

Environment

AutoSys Workload Automation

Resolution

To fix the WCC validation issue add the monitor ID user to the WorkloadAutomationAEWebService application group in EEM Application: WorkloadAutomationAE

For the agent inventory access we need to add the WCC login user or the containing global/dynamic  group to the following policies in EEM Application: WCC004

AgentAccess
ApplicationAccess

 

Additional Information

Web UI Agent Inventory