Customer finished up Primary server install against caeem.company.com, but shadow server's install does not let the customer go through to next step after providing EEM credentials.
Below error shows up
2021-03-04 16:11:29,251 [main] DEBUG com.ca.wla.ae.installer.util.HostUtils - Address reachability check failed [host={ caeem.company.com}, timeout={1000}]
2021-03-04 16:11:29,251 [main] ERROR com.ca.wla.ae.installer.logger.LogHelper - [CAUAJM_E_112125] CA EEM server(s) "caeem.company.com" configured for AutoSys are unreachable.
2021-03-04 16:11:29,251 [main] DEBUG com.ca.wla.ae.installer.logger.LogHelper - Setting the result variables:$AE_SEC_PRE_VALIDATE_RETURN_STATUS$ to:E_AE_EEMServers_Not_Reachable :$AE_SEC_PRE_VALIDATE_RETURN_MSG$ to:[CAUAJM_E_112125] CA EEM server(s) "caeem.company.com" configured for AutoSys are unreachable.
port 5250 between Autosys and EEM is open.
Release : 12.0
Component :
ICMP ping was disabled between autosys server and EEM servers in question
ICMP ping was disabled from Autosys servers to EEM server. Windows Firewall was blocking it.
To get around this, create a rule to allow ICMP ping between the nodes above and restart the install